We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Measurement and remote monitoring system.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Measurement and remote monitoring system - List of Manufacturers, Suppliers, Companies and Products | IPROS GMS

Measurement and remote monitoring system Product List

1~5 item / All 5 items

Displayed results

Continuous measurement of direct current | Early detection of signs of current changes different from normal conditions.

Utilize early detection of signs of current changes that differ from normal conditions. You can check the current values, history, and threshold notifications of the DC circuit from the monitoring base.

Before implementation, it is necessary to visit the equipment using DC power supplies to measure the current and manually record the results. After implementation, the DC current for each circuit can be monitored remotely, and the history can be treated as common data. The "iDC-SVS4" continuously measures DC current with sensors that support 30A, 50A, 100A, 250A, and 500A, and sends the measurement data to a monitoring server. Current values, load fluctuations, and past history can be checked remotely, and in combination with monitoring software, it can also respond to notifications based on set thresholds. It supports initial installation in our distribution boards and assists in reducing on-site work through load testing and equipment settings before shipment. Usage scenarios: - Monitoring DC current for equipment using DC power supplies - Checking current values and history for DC distribution boards and load circuits - Notifications based on set thresholds and checking history before and after notifications Expected effects from implementation: - Understanding current changes over time outside of patrols - Early detection of current changes that differ from normal conditions - Organizing inspection targets and confirmation details in advance to streamline equipment management We will propose configurations based on monitoring targets, the number of circuits, cable diameter, and installation environment.

  • Ammeter
  • Data Logger
  • Instrumentation and Control Systems
  • Measurement and remote monitoring system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Continuously measure direct current | Notify by email of current changes outside the set range.

Notify via email of current changes outside the set range. You can check the changes in direct current over time, which can be difficult to notice only during patrols.

When introducing DC current monitoring for equipment using a DC power supply, it is necessary to check the current range, cable diameter, number of circuits, panel space, and communication path, and to select a configuration suitable for the DC distribution board and load equipment circuits. The "iDC-SVS4" is a sensor that continuously measures DC current with support for 30A, 50A, 100A, 250A, and 500A, and sends the measurement data to a monitoring server. It allows remote confirmation of current values, load fluctuations, and past history, and in combination with monitoring software, it can also respond to notifications based on set thresholds. It supports initial installation in our distribution boards and assists in reducing on-site work through load testing and equipment settings before shipment. Usage scenarios: - Monitoring DC current for equipment using a DC power supply - Checking current values and history of DC distribution boards and load equipment circuits - Notifications based on set thresholds and checking history before and after notifications Expected benefits from implementation: - Understanding current changes over time outside of patrols - Early detection of current changes that differ from normal conditions - Organizing inspection targets and confirmation contents in advance to streamline equipment management We will propose configurations based on monitoring targets, number of circuits, cable diameter, and installation environment.

  • Ammeter
  • Data Logger
  • Instrumentation and Control Systems
  • Measurement and remote monitoring system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

DC current history measurement | Compare and confirm current values and load fluctuations over periods.

Compare and confirm current values and load fluctuations over different periods. Continuous measurement of direct current allows for remote monitoring of current values, load fluctuations, and history.

In facilities using DC power supplies, measuring and recording the circuits of DC distribution boards and load equipment on-site takes time, making it difficult to grasp changes that occur between inspections. The "iDC-SVS4" continuously measures DC current with sensors that support 30A, 50A, 100A, 250A, and 500A, and sends the measurement data to a monitoring server. Current values, load fluctuations, and past history can be checked remotely, and in combination with monitoring software, it can also respond to notifications based on set thresholds. In the event of communication failure, data is temporarily stored in a relay device and sent after communication resumes to prevent loss of history. Usage scenarios: - Monitoring DC current in facilities using DC power supplies - Checking current values and history of DC distribution boards and load equipment circuits - Confirming inspection targets and notification status before on-site visits Expected effects from implementation: - Comparing current trends before and after changes in time periods and operations - Consolidating measurement information from multiple circuits for review - Organizing inspection targets and confirmation details in advance to streamline equipment management We will propose configurations based on monitoring targets, number of circuits, cable diameter, and installation environment.

  • Ammeter
  • Data Logger
  • Power Monitoring Equipment
  • Measurement and remote monitoring system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Continuous measurement of direct current | Organizing equipment and circuits to be inspected based on current changes.

Utilize the organization of equipment and circuits to be inspected based on current changes. The current values, history, and threshold notifications of the DC circuit can be checked from the monitoring center.

In the maintenance of equipment using DC power supplies, not only the temporary values during inspections but also the time-series data of DC current accumulated during normal operation serve as fundamental information for assessing changes. The "iDC-SVS4" continuously measures DC current with sensors that support 30A, 50A, 100A, 250A, and 500A, and sends the measurement data to a monitoring server. Current values, load fluctuations, and past history can be checked remotely, and in combination with monitoring software, it can also respond to notifications based on set thresholds. In the event of communication failure, the relay device temporarily stores data and sends it after communication resumes, helping to prevent history loss. Usage scenarios: - Monitoring DC current of equipment using DC power supplies - Checking current values and history of DC distribution boards and load equipment circuits - Confirming inspection targets and notification status before on-site visits Expected effects from implementation: - Understanding current changes over time outside of patrols - Consolidating measurement information from multiple circuits for review - Organizing inspection targets and confirmation details in advance to streamline equipment management We will propose configurations based on monitoring targets, number of circuits, cable diameter, and installation environment. Applicability varies depending on current range, cable diameter, and installation/communication environment.

  • Ammeter
  • Data Logger
  • Power Monitoring Equipment
  • Measurement and remote monitoring system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Continuous measurement of direct current | Early detection of power changes in disaster prevention communication equipment

Utilize early detection of power changes in disaster prevention communication equipment. The current values, history, and threshold notifications of the DC circuit can be checked from the monitoring base.

Before implementation, it is necessary to visit disaster prevention wireless base stations and wireless relay stations to measure current and manually record the results. After implementation, direct current for each circuit can be checked remotely, and the history can be treated as common data. The "iDC-SVS4" is a sensor that continuously measures direct current with support for 30A, 50A, 100A, 250A, and 500A, and sends the measurement data to a monitoring server. Current values, load fluctuations, and past history can be checked remotely, and in combination with monitoring software, it can also respond to notifications based on set thresholds. It supports initial installation in our distribution boards and assists in reducing on-site work through load testing and equipment settings before shipment. Usage scenarios: - Monitoring direct current at disaster prevention wireless base stations and wireless relay stations - Checking current values and history of direct circuits supplying power to communication equipment - Notifications based on set thresholds and checking history before and after notifications Expected effects from implementation: - Understanding current changes over time outside of patrols - Early detection of current changes that differ from normal conditions - Utilizing normal history as reference information for inspections and BCP verification We will propose configurations based on monitoring targets, number of circuits, cable diameter, and installation environment.

  • Ammeter
  • Data Logger
  • Power Monitoring Equipment
  • Measurement and remote monitoring system

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration